N2O Wastewater System
The N2O Wastewater System provides continuous, real-time data from the biological process, allowing you to follow N2O formation and how your actions affect emissions. With direct measurements in the liquid phase, you get representative data across the entire basin.
You can currently choose between 2 generations of the N2O Wastewater System. Both systems are built on the same proven measurement technology and deliver reliable N2O data.
With the next generation, you calibrate where the sensor is located using LED guidance, without using a screen. You can connect up to 16 sensors and place them freely across your plant with a flexible cable setup. You can compare the 2 generations and see what's new below. Read more...
The N2O Wastewater System 3.0 consists of
Using System 2.0? You fit the same Sensor Head into the N2O Wastewater Sensor 2.0, which connects to the N2O Wastewater Controller 2.0.
Robust and reliable real-time N2O data
With the N2O Wastewater System, you measure directly in the biological process and gain real-time insight into the conditions driving N2O formation. This allows you to follow changes in your process, adjust aeration, and reduce N2O emissions based on what is actually happening in your plant.
Calibrate where the sensor is located
With the new generation, you calibrate where the sensor is located, using LED guidance and without a screen. It takes 5–10 minutes. Prefer a screen? You can also run the calibration from the Operator Console.
With a fully digital sensor, calibration and sensor data are stored on the sensor, and the sensor notifies you when it is time to calibrate or replace the Sensor Head.
Designed for flexible installation
You can connect up to 16 sensors in one system and place them where they give you the most value. Each Connector Unit takes up to 2 sensors and connects them to the Operator Console, and you can install as many Connector Units as you need. The system gives you a very flexible cable setup, so you can route cables around tanks and structures when designing your measurement setup.
To measure N2O with System 3.0, you need four components: a Sensor Head, a Sensor, a Connector Unit and an Operator Console. Sensor Heads are ordered separately, and you need one per sensor.
System 2.0 uses a Sensor Head, a Sensor 2.0 and a Controller 2.0.
| Feature | N2O Wastewater System 3.0 | N2O Wastewater System 2.0 |
|---|---|---|
|
Feature
Calibration
|
N2O Wastewater System 3.0
Where the sensor is located, with LED guidance (no screen), or at the Operator Console
|
N2O Wastewater System 2.0
At the controller (on screen)
|
|
Feature
Digital E2Prom
|
N2O Wastewater System 3.0
Calibrations, sensor data, and lifetime stored on sensor
|
N2O Wastewater System 2.0
No
|
|
Feature
Where data is stored
|
N2O Wastewater System 3.0
On the N2O Wastewater Operator Console (the sensor also keeps its own log)
|
N2O Wastewater System 2.0
On the N2O Wastewater Controller
|
|
Feature
System Interface
|
N2O Wastewater System 3.0
N2O Wastewater Operator Console
|
N2O Wastewater System 2.0
N2O Wastewater Controller
|
|
Feature
Sensors per System
|
N2O Wastewater System 3.0
Max 16 sensors
|
N2O Wastewater System 2.0
Max 2 sensors
|
|
Feature
Cable Length
|
N2O Wastewater System 3.0
Flexible
|
N2O Wastewater System 2.0
Max 100 m
|
|
Feature
Components
|
N2O Wastewater System 3.0
Sensor Head, Sensor, Connector Unit, Operator Console
|
N2O Wastewater System 2.0
Sensor Head, Sensor, Controller
|
| Feature | N2O Wastewater System 3.0 | N2O Wastewater System 2.0 |
|---|---|---|
|
Feature
Measurement Method
|
N2O Wastewater System 3.0
Electrochemical (Clark-type)
|
N2O Wastewater System 2.0
Electrochemical (Clark-type)
|
|
Feature
Working Range N2O-N: 0–110 mg/L
|
N2O Wastewater System 3.0
Per Sensor Head: 0–1.5 / 0–9 / 0–110 mg/L
|
N2O Wastewater System 2.0
Per Sensor Head: 0–1.5 / 0–9 / 0–110 mg/L
|
|
Feature
Detection Limit N2O-N: 0.005 mg/L
|
N2O Wastewater System 3.0
Per Sensor Head: 0.005 / 0.03 / 0.4 mg/L
|
N2O Wastewater System 2.0
Per Sensor Head: 0.005 / 0.03 / 0.4 mg/L
|
|
Feature
Temperature Range: 0–40 °C
|
N2O Wastewater System 3.0
Per Sensor Head: 0–27 °C or 27–40 °C.
|
N2O Wastewater System 2.0
Per Sensor Head: 0–27 °C or 27–40 °C.
|
|
Feature
Response Time
|
N2O Wastewater System 3.0
<65 sec
|
N2O Wastewater System 2.0
<65 sec
|
|
Feature
Affected by condensation, foam, fouling, or biofilm
|
N2O Wastewater System 3.0
No
|
N2O Wastewater System 2.0
No
|
|
Feature
Process Zones
|
N2O Wastewater System 3.0
Anaerobic, anoxic, and aerobic
|
N2O Wastewater System 2.0
Anaerobic, anoxic, and aerobic
|
Quick Enquiry
Related Products
Measure N2O directly in the liquid phase to optimize your wastewater treatment process and reduce your emissions.
Operate and calibrate your sensors where they are installed.
Collect and manage your N2O measurement data in one place.
Measure dissolved N2O with fast response time in the biological tanks of wastewater treatment plants
Collect data from up to two sensors and transmit directly to your PLC or SCADA system
The replaceable Clark-type measuring element of the N2O Wastewater Sensor
Calibrate your nitrous oxide sensor every second month
Free placement of your N2O Wastewater Controller
Robust sensor mounting for fast flowing water
Compare N2O Wastewater System generations