N2O Wastewater Operator Console installed at WWTP
N2O Wastewater Controller installed at Aarhus Vand

N2O Wastewater System

Compare N2O Wastewater System generations

The N2O Wastewater System provides continuous, real-time data from the biological process, allowing you to follow N2O formation and how your actions affect emissions. With direct measurements in the liquid phase, you get representative data across the entire basin.

You can currently choose between 2 generations of the N2O Wastewater System. Both systems are built on the same proven measurement technology and deliver reliable N2O data.

With the next generation, you calibrate where the sensor is located using LED guidance, without using a screen. You can connect up to 16 sensors and place them freely across your plant with a flexible cable setup. You can compare the 2 generations and see what's new below. Read more...

The N2O Wastewater System consists of

The N2O Wastewater System 3.0 consists of

Using System 2.0? You fit the same Sensor Head into the N2O Wastewater Sensor 2.0, which connects to the N2O Wastewater Controller 2.0.

Read more
What's new
Measurement Performance
Quick Enquiry
N2O Wastewater System

Robust and reliable real-time N2O data

With the N2O Wastewater System, you measure directly in the biological process and gain real-time insight into the conditions driving N2O formation. This allows you to follow changes in your process, adjust aeration, and reduce N2O emissions based on what is actually happening in your plant.

Calibrate where the sensor is located

With the new generation, you calibrate where the sensor is located, using LED guidance and without a screen. It takes 5–10 minutes. Prefer a screen? You can also run the calibration from the Operator Console.

With a fully digital sensor, calibration and sensor data are stored on the sensor, and the sensor notifies you when it is time to calibrate or replace the Sensor Head.

N2O Wastewater Sensor zoomed in on the sensor tip with water background
Designed for flexible installation

You can connect up to 16 sensors in one system and place them where they give you the most value. Each Connector Unit takes up to 2 sensors and connects them to the Operator Console, and you can install as many Connector Units as you need. The system gives you a very flexible cable setup, so you can route cables around tanks and structures when designing your measurement setup.

To measure N2O with System 3.0, you need four components: a Sensor Head, a Sensor, a Connector Unit and an Operator Console. Sensor Heads are ordered separately, and you need one per sensor.
System 2.0 uses a Sensor Head, a Sensor 2.0 and a Controller 2.0.

Sketch of how you connect the N2O Wastewater System 3.0
Compare N2O Wastewater System Generations
Compare N2O Wastewater System Generations
Feature N2O Wastewater System 3.0 N2O Wastewater System 2.0
Feature
Calibration
N2O Wastewater System 3.0
Where the sensor is located, with LED guidance (no screen), or at the Operator Console
N2O Wastewater System 2.0
At the controller (on screen)
Feature
Digital E2Prom
N2O Wastewater System 3.0
Calibrations, sensor data, and lifetime stored on sensor
N2O Wastewater System 2.0
No
Feature
Where data is stored
N2O Wastewater System 3.0
On the N2O Wastewater Operator Console (the sensor also keeps its own log)
N2O Wastewater System 2.0
On the N2O Wastewater Controller
Feature
System Interface
N2O Wastewater System 3.0
N2O Wastewater Operator Console
N2O Wastewater System 2.0
N2O Wastewater Controller
Feature
Sensors per System
N2O Wastewater System 3.0
Max 16 sensors
N2O Wastewater System 2.0
Max 2 sensors
Feature
Cable Length
N2O Wastewater System 3.0
Flexible
N2O Wastewater System 2.0
Max 100 m
Feature
Components
N2O Wastewater System 3.0
Sensor Head, Sensor, Connector Unit, Operator Console
N2O Wastewater System 2.0
Sensor Head, Sensor, Controller
Measurement performance (unchanged)
Measurement performance (unchanged)
Feature N2O Wastewater System 3.0 N2O Wastewater System 2.0
Feature
Measurement Method
N2O Wastewater System 3.0
Electrochemical (Clark-type)
N2O Wastewater System 2.0
Electrochemical (Clark-type)
Feature
Working Range N2O-N: 0–110 mg/L
N2O Wastewater System 3.0
Per Sensor Head: 0–1.5 / 0–9 / 0–110 mg/L
N2O Wastewater System 2.0
Per Sensor Head: 0–1.5 / 0–9 / 0–110 mg/L
Feature
Detection Limit N2O-N: 0.005 mg/L
N2O Wastewater System 3.0
Per Sensor Head: 0.005 / 0.03 / 0.4 mg/L
N2O Wastewater System 2.0
Per Sensor Head: 0.005 / 0.03 / 0.4 mg/L
Feature
Temperature Range: 0–40 °C
N2O Wastewater System 3.0
Per Sensor Head: 0–27 °C or 27–40 °C.
N2O Wastewater System 2.0
Per Sensor Head: 0–27 °C or 27–40 °C.
Feature
Response Time
N2O Wastewater System 3.0
<65 sec
N2O Wastewater System 2.0
<65 sec
Feature
Affected by condensation, foam, fouling, or biofilm
N2O Wastewater System 3.0
No
N2O Wastewater System 2.0
No
Feature
Process Zones
N2O Wastewater System 3.0
Anaerobic, anoxic, and aerobic
N2O Wastewater System 2.0
Anaerobic, anoxic, and aerobic

Quick Enquiry

    If you complete the form below, we will send you a quote as soon as possible to give you a quick price indication.

    Select Country

    How many measurement points would you like? You can fit 16 sensors to each console. We will include the needed no. of consoles.

    For which period would you like Sensor Heads and calibration kits to be included?

    We will use your e-mail for our newsletter. That's it.