N2O Wastewater Controller
The N2O Wastewater Controller shows you the temperature compensated N2O levels, emission rates, and process temperatures from up to two N2O Wastewater Sensors. Read more...
Direct Data Collection and Transmission
With the N2O Wastewater Controller, you collect data from the N2O Wastewater Sensors. You can connect the controller to your plant's PLC or SCADA system to automate the collection of data. You can also choose a USB data logger to extract data directly from the controller to a USB drive without connecting to the PLC or SCADA system.
Connect up to two sensors
You can monitor the nitrous oxide levels and emission values from up to two sensors on the controller and adjust the settings with the TFT touch screen.
We have set up standard fixed model parameters to calculate the emission levels in the controller. If you require more accurate emission values, you can add an emission module with dynamic input parameters.
Autozero feature
From 1 October 2023, the N2O Wastewater Controller is equipped with Autozero. The Autozero feature aims to ensure that negative values do not impact your emissions reporting by performing an automatic zero point calibration. So you can rest assured that the sensor is performing as planned, and your nitrous oxide emissions reporting will benefit from precise, correct, and clean data.
Sensor calibration
When you perform the sensor calibration every second month, you simply access the controller’s system menu onsite and follow the N2O Calibration Kit manual and/or the N2O Calibration video guides.
Mounting the N2O Wastewater Controller
You will receive the controller with a mounting plate as standard. You can add a pipe mounting kit and a weather protection canopy depending on where you place the N2O Wastewater Controller.
Feature | Description |
---|---|
Feature
Sensor inputs
|
Description
2 x N2O Wastewater Sensor with built-in temperature sensor
|
Feature
Other inputs
|
Description
Optional: Air flow (m3/h), 4..20 mA | Optional: 2 x Air flow ON/OFF (Binary input - potential-free contact)
|
Feature
Sensor output
|
Description
2 x temperature compensated N2O value (N2O-N[mg/L])
|
Feature
Sensor emission output
|
Description
2 x Emission calculations (N2O-N [mg/m3/d]) with standard fixed model parameters | Optional: Dynamic input parameters
|
Feature
Other outputs
|
Description
Internet, ModBus (serial or TCP) | Optional: 2 x N2O Wastewater temp. sensor | Optional: PROFIBUS-DP | Optional: USB datalogging - software required
|
Feature | Description |
---|---|
Feature
Controller
|
Description
TFT touch screen controller
|
Feature
Box size and weight
|
Description
301.5 x 283.2 x 120.5mm, 3.2 kg
|
Feature
Housing
|
Description
Surface-mounted case made of plastic (ABC) | IP67 - dust-resistant and waterproof
|
Feature
Mounting
|
Description
Multiple holes for surface or pipe mounting - mounting plates and weather protection canopy available
|
Feature
Electrical safety
|
Description
According to EN 61010, part 1: Overvoltage category III, pollution degree 2
|
Feature
Power supply
|
Description
AC 110 to 240 V + 10/15%; 48 to 63 Hz, 55 VA
|
Related Products
Measure dissolved N2O with fast response time in the biological tanks of wastewater treatment plants
Collect data from up to two sensors and transmit directly to your PLC or SCADA system
A Clark-type electro-chemical sensor that measures the concentration of nitrous oxide
Calibrate your nitrous oxide sensor every second month
Free placement of your N2O Wastewater Controller
Robust sensor mounting for fast flowing water
Measure dissolved N2O directly in bulk water